Shenzhen Fama Intelligent Equipment Co.,Ltd&Chevy light co.,ltd

Sales & Support
Request A Quote - Email
Select Language
English
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsIntelligent Traffic Controller

28 Outputs Independent Traffic Controller

Certification
Good quality 200mm Traffic Light Series for sales
Good quality 200mm Traffic Light Series for sales
I'm Online Chat Now

28 Outputs Independent Traffic Controller

China 28 Outputs Independent Traffic Controller supplier

Large Image :  28 Outputs Independent Traffic Controller

Product Details:

Place of Origin: shenzhen
Brand Name: FAMA/CHEVY LIGHT
Certification: CE(EN12368,LVD,EMC), GB14887-2011,IP55
Model Number: FM-XHJ-28

Payment & Shipping Terms:

Minimum Order Quantity: 1pcs
Packaging Details: neutral packing Carton, Export standard Carton
Delivery Time: 7-10days
Payment Terms: L/C,T/T,Western Union,Paypal
Supply Ability: 1000 Set/Sets per Month Traffic Signal Controller
Contact Now
Detailed Product Description

Intelligent traffic signal controller is used to control the traffic flow in multiple ways at an intersection.
Intelligent traffic signal Controller can used for individual  intersection control, or as a system component of a comprehensive  Traffic Management System.
Our Controller has Independent and  and networked two kinds.
Independent Traffic Controller Features:
    Built-in central control system to ensure work stability 
    Easy for maintenance and function extension by adopting modular design 
    44 outputs and 16 light groups with work current of 10A
    Extensible RS-232,RS-485 interface to communicate with upper computer 
    Able to adjust, check and set while  working 
    2*99 work periods for workday and holiday setting 
    32 working menus used for any period 
    Each menu can include 99 steps and 1~255s each step 
    The flashing state, frequency and time of each signal light can be set or adjusted. 
    Flashing time and frequency can be adjusted according to needs. 
    Able to enter yellow flashing state at any time in case of emergency 

    Manual control can be achieved by specific menu or while under working.

 

1Product Function and Technical Feature:

Built-in central control system to ensure work stability;          2*48 work periods for workday and holiday setting;

Easy for maintenance and function extension by modular design;

Input  AC110V and AC220V, Can be changed by the switch;    Yellow flashing or close the signal can be setup at night;

Adopt RS-232 or LAN port to communicate with upper computer;

32 working menus used for any period(among 1~30 numbers customs can set it by themselves);

The flashing state, frequency and time of each green signal light can be setup or adjusted;

Can modify the current pace of running time in the running state immediately;

Full red, yellow flashing, step by step manual,jump in the manual,remote manual function(optional);

Be equipped with the hardware fault testing function(Red Light fails,Green lights up test),down grade to Yellow flash status and cut down the Red&Green light power supply when the fault happens.(Optional)

The output part adopts zero-test technology,Change of state is zero state switch in communication,Make the drive more safe and reliable;

Each output all the way with independent lightning protection circuit;

Installation testing capabilities,can test to confirm installation correctness for each lamp when installation at intersection;

The clients can set up 30 menu to be backup and recovery ;

The setup software can operation on the computer offline,Project data can be stored on the computer and can be copied.

2Technical Parameters:

Items

Technical Parameters

Executive Standard

GB25280-2010

Working Voltage

AC110V/220V±20% (changed by switch)

Working Frequency

47Hz~63Hz

No-load power

≤15W

The whole controller rated load power

2200W

Motor operation sequence(special timing state should be statement before production)

all Red(can setup) →green light→green flash can setup) →yellow light→Red light

Pedestrian signal operation sequence

all Red(can setup) →green light→Green flash(can setup)→Red light

Rated drive current in each way

3A

surge current in each way

≥100A

The largest output channel independently

44

The largest output way independently

16

working menus

32

Can be setup menus number

30

The largest number of each meus

24

The largest number of timers in each day

48

Running time in each step

1~255

Full red transition time

0~5S

Yellow light transition time

1~9S

Green flashing time

0~9S

OperationalTemperatureRange

-40℃~+80℃

Relative Humidity

<95%

Setting Plan Saving Time(the electricity was turned off)

10 years

Time Error

Error/year<2.5 minutes (25±1℃)

Inner Cabinet Dimension

 

Outer Cabinet Dimension

 

3. Operation Panel button function introduction 

28 Outputs Independent Traffic Controller

 

 

4. Setup Instruction

4.1 Date Setting

Press Function button to make the date button is light,the digital tube will display the current date,press the Plus and Minus, the cursor will be moved to the digital which you want to modify. Press SAVE to save the plane after the completion of the modified,if press Exist, the exist the current setting cannot be saved.

Press Function, we will move to next stage-TimeSet:

28 Outputs Independent Traffic Controller

 

4.2  Time Setting:

Press Function to time set,when the indicator light is lighting, the digital tube will display the current time(Hour,minute,second,day of the week),

Press the Plus and Minus to change the flashing digital,Press SAVE to save the plane after the completion of the modified,if press Exist, the exist the current setting cannot be saved.

Press Function can be moved to next set—Flash set/ Transition state parameter Settings:

28 Outputs Independent Traffic Controller

 

4.3  Transition state parameter Settings

Press Function enters into the transition state parameter Settings,here we can be set up  the green flashing time,the transition time of full red and yellow.,after the indicator lamp lights up,The digital tube will display the current flash time,press the Plus and Minus to modify the flashing time,Press SAVE to save the plane after the completion of the modified,if press Exist, the exist the current setting cannot be saved.

Press Function can be moved to next set—workday plan setting:

Note:we cab setupt the right simulation intersection to finish this stage.

direction stands for direction,Left and Right can be used to choose the light,Yes means ok, No means this light will be not setup this function:

28 Outputs Independent Traffic Controller

 

 

4.4  Weekday scheme settings

Press Function button to enter the weekday scheme settings, The running time scheme can be setted from every Monday to Friday ! ( it can be setted up to 48 programs every day ), after the indicator lighten, The digits tube will display the current flashing time. We can modify the flashing digital through the Plus and Minus button, and press the left and right  button can move the cursor to modify the digital. Note : we can’t modify the setting time at the first period time, when the time was setted to 24:00, that means the period time has been finished. After modification, , press the save button to save it. If you press the Exist button to exit current settings (non-preservation), Press the function key to enter the next state of holidays cheme settings.  

28 Outputs Independent Traffic Controller

 

 

4.5  Holidays scheme settings

Press the function button to enter the holidays scheme settings, the period time scheme can be setted from Saturday and Sunday ( you can set up to 48 period time at most) after the indicator lighten, The digits tube will display the current flashing time. We can modify the flashing digital through the Plus and Minus button, and press the left and right  button can move the cursor to modify the digital. Note : we can’t modify the setting time at the first period time, when the time was setted to 24:00, that means the period time has been finished. After modification, , press the save button to save it. If you press the Exist button to exit current settings (non-preservation), Press the function key to enter the next state of holidays cheme settings.

of holidays cheme settings.  

 

28 Outputs Independent Traffic Controller

 

 

 

4.5  Setup Menu

Press the Funciton button to enter the menu program settings, the digits tube will be displays the digital presentation from left to right. Menu number ( we can set up to 30 sets programs at most). Step (setted up to 24 steps at most), and the current steps duration, when setting up this items, we can set up the green light for performed requirements as per the right side of simulated intersection, Direction, left and right are choose to the corresponding light, Yes means selected the light, By setting the current time step continuously,  which can be setted the running time for traffic signal light, after finished that, press save key to enter the next step settings by automaticly, the same setting methods as above, and so on. When the steps time is set up to 0, press save key, and the current menu will be automatic end, then it will be back to the current operating state.

After changed the menu, we can modify the other menu, Pls kindly see the notes as below,

          1, If the traffic signal light have conflict on release, such as green conflict /yellow flashing lights at this time, which can’t be saved, you need to choose the release traffic signal light again .

          2, The total of menu number is 32 , you can set up it by yourself from 1-30,  and the number of 31 is fixed yellow flashing time, the Number of 32 menu means the off menu, while the number 31 and number 32 menu can be exchanged   between weekday scheme settings and holidays scheme settings.

The first step:

Press the left and right buttons to modify the digital as your needs, and press the plus and minus button to choose any digital what you want. Forexample, you can change the original setted time 9s to 8s or others. After setted as the picture ( the digital indicate the numbers), we can move on next setup

1. Enter to Number 01 menu settings. 

28 Outputs Independent Traffic Controller

28 Outputs Independent Traffic Controller

28 Outputs Independent Traffic Controller

28 Outputs Independent Traffic Controller

                                                                 2.To set Menu 02

28 Outputs Independent Traffic Controller

28 Outputs Independent Traffic Controller

28 Outputs Independent Traffic Controller

28 Outputs Independent Traffic Controller

 

5. Special Function Operations:

Introduction to the function of side-door switches and buttons

 

28 Outputs Independent Traffic Controller

 

Remote controller operation introduction ( notes: it is as per customers requirements to match)

1, The picture shows the remote controller as the right picture, the effective distance is about200m.

 

2, The left black parts is power supply for remote controller. 

3, The Capitals of ABCD on the remote controller was corresponding function as below, 

Capitals

A

B

C

D

Function

Manually

Full red

Yellow flashing

Exit

 

                  28 Outputs Independent Traffic Controller

 

Six,The Common faults and solutions for controller

Item

Failure phenomena

Solutions scheme

1

The controller doesn’t work ,and has no power .

The fuse may be cut off. Users need to use a fuse of5Aor main fuse of10Ato change it. Main fuse is in the power socket.

2

The signal lights in the road intersection keep flashing amber and it is because of setting.

The reason maybe is the phasis setting, and there are have green conflicts ( the panel green conflict indicated light). You need to reset the phasis programs again.

Seven,Packing List:

Item

Spare parts description

Quantity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8. Signal Controller Wiring Diagram

 

28 Outputs Independent Traffic Controller

Outputs port corresponding graph:

28 Outputs Independent Traffic Controller

The digital returns the interface definition  (notes: The same dedinition for 4pcs driver interface. )

Item

1

2

3

4

5

6

7

Description

Turn Left Red light

Left turn yellow light

Turn Left green light

Common Port

Go Straight Red light

Go straight Yellow light

Go straight green light

8

9

10

11

12

13

14

15

Common port

Right turn Red light

Right turn yellow light

Right turn Green light

Common Port

Pedestrian red light

Pedestrian green light

Common Port

9. The Whole Cabinet Wiring Diagram 

28 Outputs Independent Traffic Controller

 

Contact Details